 600W Single Output With Parallel Function
Features :
SCN-600
series
AC input range selected by switch Protections: Short circuit / Overload / Over voltage / Over temp. High reliability/ Low ripple noise Built-in remote sense function Built-in remote ON-OFF control Built-in parallel operation function Can adjust from 20~100% output voltage by external control 1-5V Forced air cooling by built-in DC fan Case coating with paint 2 years warranty
SPECIFICATION
ORDER NO. SAFETY MODEL NO. DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (max.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC
(Note. 4)
SCN-600-05 600S-N005 5V 100A 0 ~ 100A 500W
SCN-600-12 600S-N012 12V 50A 0 ~ 50A 600W 120mVp-p
SCN-600-15 600S-N015 15V 40A 0 ~ 40A 600W 150mVp-p
SCN-600-18 600S-N018 18V 33A 0 ~ 33A 594W 180mVp-p
SCN-600-24 600S-N024 24V 25A 0 ~ 25A 600W 240mVp-p
SCN-600-48 600S-N048 48V 12A 0 ~ 12A 576W 480mVp-p 1.0% 0.5% 0.5%
RIPPLE & NOISE (max.) Note.2 100mVp-p
5.0% typical adjustment by potentiometer 1.0% VOLTAGE TOLERANCE Note.3 1.5% 0.5% 1.0% 0.5% 0.5%
20~100% adjustment by 1~5VDC external control 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
SETUP, RISE, HOLD UP TIME 800ms, 50ms, 16ms at full load 90 ~ 130VAC / 180 ~ 260VAC selected by switch, 260 ~ 370VDC 47 ~ 63Hz 77% 11A / 115VAC 60A / 230VAC 3.5mA / 240VAC 101 ~ 115% 110 ~ 135% rated output power Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover 110 ~ 135% follow to output set up point Protection type : Shut down o/p voltage, re-power on to recover >100 / measure by heat sink, near transformer Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +65 (Refer to output load derating curve) 20% ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.04% / (0 ~ 50 ) 10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, CSA22.2, IEC60950 approved I/P-O/P, I/P-FG:1500VAC I/P-O/P, I/P-FG, 100M Ohms / 500VDC / 25 / 70% RH 80% 7.0A / 230VAC 81% 82% 85% 87%
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION Compliance to FCC part 15 class A ---HARMONIC CURRENT EMS IMMUNITY MTBF DIMENSION PACKING SPECIAL FUNCTION ---120Khrs min. MIL-HDBK-217F (25 ) 291*132*68mm (L*W*H) 2.6kg; 8pcs/ 24kg/ CARTON DC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual)
OTHERS
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2.Tolerence: includes set up tolerance, line regulation, load regulation. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
File Name:SCN-600-SPEC 2008-05-06
600W Single Output With Parallel Function
Mechanical Specification
SCN-600
series
Unit:mm
291 200 199.5
L N FG
50.5 41
15.5
68
AC INPUT
#6-32-4 M3(NUT)x3H-4
30
15
POS+
291 9 250 M3(NUT)x3H-4 Air flow direction 32
DC OUTPUT
POS
9.5
AC INPUT
BOTTOM SIDE
M6.0
NEG
Derating Curve
External DC Control VS Output Voltage
Vout
7.5
115
132
O.V.P.
100
100
OUTPUT VOLTAGE (%)
80
LOAD (%)
non-linear
60 40
50
20
-10
0
10
20
30
40
50
60
V 1 2 3 4 5
Ta (
)
EXTERNAL VOLTAGE(Typical)
File Name:SCN-600-SPEC 2008-05-06
VS+ VSVCI VCO GND PAR GND INH LED NEGV ADJ
500~600W Parallel (N+1) With PFC Function
Control terminal instruction manual
SCP-600
series
LOAD
LOAD
LOAD
LOAD
VS+ VSVCI VCO PG PAR GND INH
VS+ VSVCI VCO PG PAR GND INH
VS+ VSVCI VCO PG PAR GND INH
ON/OFF SWITCH
VS+ VSVCI VCO PG PAR GND INH
H:ON L:OFF
USING INTERNAL VOLTAGE CONTROL
REMOTE SENSING
ON/OFF CONTROL BY SWITCH
ON/OFF CONTROL BY TRANSISTOR
Vout
GOOD FAIL : LED OFF : LED ON
O.V.P. 120% (Typ.)
120 100
LOAD LOAD
OUTPUT VOLTAGE (%)
80 60 40 20
Non-Linear
VS+ VSVCI VCO PG PAR GND INH
40V / 0.5A MAX.
VS+ VSVCI VCO PG PAR GND INH
DC 1-5V
POWER GOOD SIGNAL
OUTPUT VOLTAGE ADJUST WITH DC 1-5V
1
2
3
4
5
6
V
EXTERNAL VOLTAGE (DC)
LOAD
LOAD
VS+ VSVCI VCO PG PAR GND INH
VS+ VSVCI VCO PG PAR GND INH
VS+ VSVCI VCO PG PAR GND INH
VS+ VSVCI VCO PG PAR GND INH
VS+ VSVCI VCO PG PAR GND INH
VS+ VSVCI VCO PG PAR GND INH
PARALLEL OPERATION WITH REMOTE SENSING
PARALLEL OPERATION WITHOUT REMOTE SENSING
File Name: SCP-600-SPEC 2008-05-06


▲Up To Search▲   

 